소형 세이프티 리미트 스위치 |
|
D4N
(생산중지예정 2025-03-31)
|
|
|
|
|
|
|
접점 구성을 기존의 1NC/1NO, 2NC에 더하여 2NC/1NO, 3NC의 3접점 타입을 구성 (MBB 사양 추가) 공수 절감을 실현하여 교환 작업이 용이한 M12 커넥터 타입 발매 접촉신뢰성이 높은 Au클래드 접점을 표준 채용 - 일반부하, 미소부하에 모두 대응 납, 카드뮴, 6가 크롬을 사용하지 않아 환경 부하 저감 EN115, EN81-1 대응 저속 동작 타입, 스냅 동작 타입 모두 Zb접점 구성 UL, EN(TUV), CCC 규격 취득
일부 상품은 2025 년 3 월 수주 종료 예정
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
Service Info |
|
대체상품보기 |
|
대체상품이 존재하지 않습니다.
|
|
|
|
|
|
Ratings and Specifications
Degree of protection *1 |
IP67 (EN60947-5-1) |
Durability *2 |
Mechanical |
15,000,000 operations min. *5 |
Electrical |
500,000 operations min. (3 A resistive load at 250 VAC) *3
300,000 operations min. (10 A resistive load at 250 VAC) |
Operating speed |
1 to 500 mm/s (D4N-1120) |
Operating frequency |
30 operations/minute max. |
Contact resistance |
25 mΩ max. |
Minimum applicable load *4 |
1 mA resistive load at 5 VDC (N-level reference value) |
Rated insulation voltage (Ui) |
300 V |
Rated frequency |
50/60 Hz |
Protection against electric shock |
Class II (double insulation) |
Pollution degree (operating environment) |
3 (EN60947-5-1) |
Impulse withstand
voltage
(EN60947-5-1) |
Between terminals of
same polarity |
2.5 kV |
Between terminals of
different polarity |
4 kV |
Between each terminal
and non-current carrying
metallic parts |
6 kV |
Insulation resistance |
100 MΩ min. |
Contact gap |
Snap-action: 2 × 0.5 mm min.
Slow-action: 2 × 2 mm min. |
Vibration resistance |
Malfunction |
10 to 55 Hz, 0.75 mm single amplitude |
Shock resistance |
Destruction |
1,000 m/s2 min. |
Malfunction |
300 m/s2 min. |
Conditional short-circuit current |
100 A (EN60947-5-1) |
Conventional free air thermal current (Ith) |
10 A (EN60947-5-1) |
Ambient operating temperature |
-30 to 70°C (with no icing) |
Ambient operating humidity |
95% max. |
Weight |
Approx. 82 g (D4N-1120)
Approx. 99 g (D4N-5120) |
Note:
1. The above values are initial values.
2. Once a contact has been used to switch a standard load, it cannot be used for a load of a smaller capacity.
Doing so may result in roughening of the contact surface and contact reliability may be lost.
*1.The degree of protection is tested using the method specified by the standard (EN60947-5-1). Confirm that sealing properties are sufficient for the operating conditions and environment beforehand. Although the switch box is protected from dust or water penetration, do not use the D4N in places where foreign material such as dust, dirt, oil, water, or chemicals may penetrate through the head. Otherwise, accelerated wear, Switch damage or malfunctioning may occur.
*2.The durability is for an ambient temperature of 5 to 35°C and an ambient humidity of 40% to 70%. For more details, consult your OMRON representative.
*3.Do not pass the 3 A, 250 VAC load through more than 2 circuits.
*4.This value will vary with the switching frequency, environment, and reliability level. Confirm that correct operation is possible with the actual load beforehand.
*5.The mechanical durability of fork lever lock models is 10,000,000 operations min.
Caution: In the interenst of product improvement, specifications are subject to change without notice.
|
|
|
|
|
|